Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Braz. dent. sci ; 26(4): 1-7, 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1523154

ABSTRACT

Objective: The study aimed to develop a cell phone application entitled: "Total Prosthesis Manual ­ Rehabilitating smiles", as an auxiliary teaching tool for teachers and students through digital technology, with a smartphone. Material and Methods: The tool was structured on the "Application Factory website", which allows the creation of mobile applications in different formats, with broad and interactive features on IOS and Android platforms. The expository format of the content is in slide format, containing descriptive theory and images about the stages of making a complete prosthesis; from necessary materials, photos and descriptive guidance of the steps. Results: The application is a complementary teaching resource to assist undergraduate and postgraduate students and professionals working in the area of complete prosthetics. The theoretical and practical content selected for the application covered all stages of understanding, development and possible complications associated with the manufacture of a complete bimaxillary prosthesis, from planning, impressions, models, orientation plans, tooth assembly, adaptations and delivery. Conclusion: The application provided a low-cost, expandable and easy-to-use teaching resource for teaching complete dentures. It is essential to develop various analyzes such as user experience tests, application effectiveness, development of new technologies and improvement of techniques, so that their potential for enriching learning in complete dentures and dentistry in general can be verified.(AU)


Objetivo: O estudo teve como objetivo desenvolver um aplicativo de celular intitulado: "Manual de Prótese Total ­ Reabilitando sorrisos", como uma ferramenta didática auxiliar para professores e alunos por meio da tecnologia digital, com smartphone. Material e Métodos: A ferramenta foi estruturada no "site da Fábrica de Aplicativos", que permite a criação de aplicativos móveis em diversos formatos, com recursos amplos e interativos nas plataformas IOS e Android. A modalidade expositiva do conteúdo é em formato de slides, contendo teoria descritiva e imagens sobre as etapas de confecção de uma prótese total; a partir de materiais necessários, fotos e orientação descritiva das etapas. Resultados: O aplicativo é um recurso didático complementar para auxiliar estudantes de graduação, pós-graduação e profissionais que atuam na área de prótese total. O conteúdo teórico e prático selecionado para a aplicação visou todas as etapas de compreensão, desenvolvimento e possíveis complicações associadas à confecção de uma prótese total bimaxilar, desde o planejamento, moldagens, maquetes, planos de orientação, montagem dos dentes, adaptações e entrega. Conclusão: O aplicativo trouxe um recurso didático de baixo custo, expansível e fácil de usar para o ensino de próteses totais. É fundamental desenvolver diversas análises como testes de experiência do usuário, eficácia de aplicação, desenvolvimento de novas tecnologias e aprimoramento de técnicas, de forma que possa ser verificado seu potencial de enriquecimento do aprendizado em prótese total e odontologia em geral(AU)


Subject(s)
Humans , Educational Technology , Denture, Complete , Education, Dental , Mobile Applications , Education, Distance , Dentists/education
2.
Braz. dent. sci ; 25(3): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1373077

ABSTRACT

Objective: Thermally activated acrylic resins (RAATs) are widely used in dentures as a base material due to their good dimensional stability and biocompatibility. However, their low thermal conductivity is a disadvantage, as it affects acceptance when using dental prostheses. Thus, the objective of this work was to measure the conduction heat in RAATs with and without incorporation of silica and silver nanoparticles (NP) and rigid reline (RR). Material and Methods: For this, samples were made and divided into 10 groups (n = 6). The first five groups were 2-mm-thick samples: G1 (RAAT control), G2 (RAAT + RR control), G3 (RAAT and NP + RR), G4 (RAAT + RR and NP), and G5 (RAAT and RR modified by NP). In the other five groups, 8-mm-thick samples were made: G6 (RAAT control), G7 (RAAT + RR control), G8 (RAAT and NP + RR), G9 (RAAT + RR and NP), and G10 (RAAT and RR modified by NP). The heat that cross the surface of the specimens was quantified using a wireless device. The data were submitted to two-factor ANOVA statistical analysis and Tukey ́s test with a 5% significance level. Results: After measuring the temperature variation as a function of time, it can be observed that there was a statistically significant difference for thermal conduction between the control groups and those modified with NP. Conclusion: Thus, it was possible to conclude that the NP improved the heat conduction in RAAT and in the RR because the nanoparticles have a higher thermal conductivity. (AU)


Objetivo: As resinas acrílicas termicamente ativadas (RAATs) são amplamente utilizada em próteses dentárias como material de base, pois possuem uma boa estabilidade dimensional e biocompatibilidade. Porém, como desvantagem, possuem baixa condutividade térmica, o que prejudica a aceitação do uso de próteses dentárias. Assim, o objetivo deste trabalho foi medir a condução de calor em RAAT com e sem incorporação de nanopartículas de sílica e prata (NP) e reembasador rígido (RR). Material e Métodos: Para isso, foram confeccionadas amostras que foram divididas em 10 grupos (n=6). Os primeiros cinco grupos eram amostras de 2 mm de espessura: G1 (RAAT controle), G2 (RAAT + RR controle), G3 (RAAT e NP + RR), G4 (RAAT + RR e NP) e G5 (RAAT e RR modificados por NP). E nos outros cinco grupos foram feitas amostras com espessura de 8 mm: G6 (RAAT controle), G7 (RAAT + RR controle), G8 (RAAT e NP + RR), G9 (RAAT + RR e NP) e G10 (RAAT e RR modificados por NP). O calor percorrido pela superfície dos corpos ­ de prova foi quantificado por meio de um dispositivo sem fio. Os dados foram submetidos à análise estatística ANOVA dois fatores e teste de Tukey com 5% de significância. Resultados: Após medir a variação da temperatura em função do tempo, pode-se observar que houve diferença estatisticamente significante para a condução térmica entre os grupos controle e os modificados com NP. Conclusão: Assim, foi possível concluir que a NP melhorou a condução de calor na RAAT e no RR, pois as nanopartículas apresentam maior condutividade térmica. (AU)


Subject(s)
Thermal Conductivity , Acrylic Resins , Nanoparticles , Metal Nanoparticles
3.
Braz. dent. sci ; 24(2): 1-7, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1177576

ABSTRACT

Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain. (AU)


Objetivo: Avaliar o efeito da altura da fibromucosa na distribuição de tensões e deslocamento das próteses totais mandibulares durante a carga unilateral posterior, carga bilateral posterior e orientação anterior usando a análise por elementos finitos (FEA). Material e métodos: Modelos virtuais 3D foram confeccionados para simular a tensão gerada durante diferentes movimentos mandibulares em uma prótese total. Os contatos foram simulados de acordo com a fisiologia, sendo considerados perfeitamente unidos entre os ossos corticais e medulares; e entre o osso cortical e a mucosa. O contato friccional não linear foi utilizado entre a base total da prótese e a fibromucosa, permitindo que a prótese deslizasse sobre o tecido. A base do osso cortical foi fixada e a carga de 100 N aplicada como carga unilateral, carga bilateral posterior e simulação de guia incisiva anterior. Os resultados foram calculados em tensão máxima principal (MPa), microdeformação (mm/mm) e deslocamento total (mm). Os resultados numéricos foram convertidos em mapas colorimétricos e organizados de acordo com as escalas correspondentes. Resultados: A tensão gerada em todas as situações foi diretamente proporcional à altura da fibromucosa. Os resultados de tensão máxima principal demonstraram maior magnitude durante a carga anterior, posterior unilateral e posterior bilateral, respectivamente. Apenas a carga unilateral posterior demonstrou aumento da microdeformação óssea, independente da altura da fibromucosa. O deslocamento da prótese foi menor sob carga bilateral posterior. Conclusão: A carga bilateral posterior é indicada para prótese total, pois permite menor deslocamento da prótese, menor concentração de tensões na base da prótese e menor microdeformação óssea (AU)


Subject(s)
Finite Element Analysis , Dental Occlusion , Denture, Complete
4.
Braz. dent. sci ; 24(4): 1-7, 2021. ilus
Article in English | LILACS, BBO | ID: biblio-1337660

ABSTRACT

Digital dentistry has gained space in several dental specialties. It is possible to achieve excellent results with the digital workflow, which combines the efficiency of the restorative material with a greater marginal adaptation. This study aimed to report a clinical case through the digital workflow, with a faster and clinically acceptable prosthetic resolution. In this clinical case report, digital workflow allowed a faster and clinically acceptable prosthetic resolution. A 45-year-old female patient reported cementation failure of the prosthetic crown on tooth 14. As it was a vital tooth, the tooth received a total crown preparation. In the same clinical session, the patient's mouth was scanned then a capture software obtained a virtual model. After, the design software planned a digital "diagnostic wax-up", so a leucitic ceramic was chosen for the rehabilitation. The ceramic block was milled and receive stain and glaze, dispensing the prosthesis laboratory. Then, the adhesive cementation was performed with a dual-polymerized resin cement. The final crown had ideal adaptation, with no need for interproximal and occlusal adjustments, with an excellent marginal fit. Within the limitations of this study, this case report showed that the digital workflow allowed a favorable result in a shorter working time, which brought back function and aesthetics, without the need for interproximal and occlusal adjustments. (AU)


A odontologia digital vem ganhando espaço em diversas especialidades odontológicas. Com o fluxo de trabalho digital, é possível alcançar excelentes resultados na reabilitação protética, combinando a eficiência do material restaurador com a adaptação marginal proporcionada pela odontologia digital. O objetivo desse estudo foi relatar um caso clínico através do fluxo de trabalho digital, com uma resolução protética mais rápida e clinicamente aceitável. Paciente do sexo feminino, 45 anos, relatou falha de cimentação da coroa protética do dente 26. Por ser um dente vital, o dente recebeu um preparo de coroa total e os dentes foram escaneados e um software de captura obteve um modelo virtual. Posteriormente, o software de projeto planejou um "enceramento diagnóstico" digital, sendo escolhida uma cerâmica leucítica para a reabilitação. O bloco cerâmico foi fresado e recebeu acabamento, maquiagem e glaze pelo próprio dentista, dispensando um técnico laboratorial de prótese dentária. Em seguida, foi realizada cimentação adesiva definitiva. Este relato de caso mostra que, dentro das limitações desse estudo, o fluxo digital permite um resultado favorável em um menor tempo de trabalho, devolvendo a função e estética, sem necessidade de ajustes interproximais e oclusais (AU)


Subject(s)
Humans , Female , Adult , Dental Prosthesis , Computer-Aided Design , Esthetics, Dental
5.
Braz. dent. sci ; 23(4): 1-7, 2020. ilus
Article in English | BBO, LILACS | ID: biblio-1122343

ABSTRACT

Head and neck cancer occupy the seventh place among the most common neoplasms in the world, with an annual incidence of approximately 640,000 new cases. Radiotherapy treatment has been highlighted, because there is greater tissue preservation, possibility of regression of the disease, decreased tumor volume, prevention of possible tumor recurrences and metastases, and even total cancer cure, but patients undergoing radiotherapy are at high risk of osteoradionecrosis if they perform surgical interventions in the region, such as dental implants and dental extraction, making prosthetic rehabilitation of partially edentulous patients after treating oral cancer something complex and often omitted; although it is a crucial factor in restoring oral function. Thus, the aim of the present study was to describe the planning, treatment and follow-up of a twelve-month prosthetic approach to rehabilitate the lower arch shape and function of a partially edentulous patient undergoing head and neck radiotherapy with a full denture mucus supported and tooth retained. After twelve months of follow-up, it was possible to evidence the functional and aesthetic clinical success, with preserved occlusal pattern, soft and bone tissue around and dental roots. (AU)


O câncer de cabeça e pescoço ocupa o sétimo lugar entre as neoplasias mais comuns do mundo, com uma incidência anual de aproximadamente 640.000 novos casos. O tratamento com radioterapia tem se destacado, pois há maior preservação tecidual, possibilidade de regressão da doença, diminuição do volume tumoral, prevenção de possíveis recorrências e metástases tumorais e até cura total do câncer, mas os pacientes submetidos à radioterapia apresentam alto risco de osteorradionecrose se realizar intervenções cirúrgicas na região, como implantes dentários e extração dentária, fazendo com que a reabilitação protética, de pacientes parcialmente dentados depois de tratar o câncer bucal, algo complexo e frequentemente omitido; embora seja um fator crucial para o reestabelecimento da função oral. Assim, o objetivo do presente estudo foi descrever o planejamento, tratamento e acompanhamento de doze meses de uma abordagem protética para reabilitar forma e função do arco inferior de um paciente parcialmente desdentado, submetido a radioterapia de cabeça e pescoço, com o uso de uma prótese total mucossuportada e dente retida. Após doze meses de acompanhamento, foi possível evidenciar o sucesso clínico funcional e estético, com padrão oclusal, rebordo alveolar e remanescentes dentários preservados (AU)


Subject(s)
Humans , Radiotherapy , Denture, Overlay , Head and Neck Neoplasms , Mouth Rehabilitation
6.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1008364

ABSTRACT

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Subject(s)
Electron Microscope Tomography , Flexural Strength , Hydrofluoric Acid
7.
Braz. dent. sci ; 21(3): 302-306, 2018. tab
Article in English | LILACS, BBO | ID: biblio-911402

ABSTRACT

Objective: Evaluate the influence of different disinfection methods on the dimensional stability of temporary acrylic resin crowns. Material and Methods: A metallic die with two different marks at the margin was used to prepare the specimens with two different resins (bis-acrylic resin-Structur, acrylic resin-Dencrilay). They were divided into eight groups (n=8), determined according to the disinfection methods (microwave, acetic acid, 1% hypochlorite) and control. The marginal adaptation was recorded using an optical microscope (50X) comparing two different marks on the margin of the crowns with 2 points along the entire circumferential margin before and after disinfection methods. Results: Results were compared statistically by ANOVA and Tukey's test (p≤0.05). The two-way ANOVA showed statistical difference between types of materials. No significant differences were found between disinfection methods and interaction of factors. Conclusion: All procedures affected the marginal adaptation however temporary crowns made by bis-acrylic resin demonstrate higher dimensional stability. (AU)


Objetivo: Avaliar a influência de diferentes métodos de desinfecção na estabilidade dimensional de coroas temporárias de resina acrílica. Material e Métodos: um molde metálico com duas marcas diferentes na margem foi utilizado para preparar os espécimes com duas resinas diferentes (resina bis-acrílica - estrutura, resina acrílica-Dencrilay). Eles foram divididos em oito grupos (n = 8), determinados de acordo com os métodos de desinfecção (microondas, ácido acético, 1% de hipoclorito) e controle. A adaptação marginal foi registrada usando um microscópio óptico (50X) comparando duas marcas diferentes na margem das coroas com 2 pontos ao longo de toda a margem circunferencial antes e após os métodos de desinfecção. Resultados: os resultados foram comparados estatisticamente por ANOVA e teste de Tukey (p≤0,05). A ANOVA de dois fatores mostrou diferença estatística entre os materiais utilizados. Não foram encontradas diferenças significativas entre os métodos de desinfecção e a interação dos fatores. Conclusão: Todos os procedimentos afetaram a adaptação marginal, porém as coroas temporárias feitas em resina bis-acrílica demonstram maior estabilidade dimensional. (AU)


Subject(s)
Acrylic Resins , Biomedical and Dental Materials , Dental Materials , Disinfection , Tooth Crown
8.
Braz. dent. sci ; 19(2): 139-144, 2016. ilus
Article in English | LILACS | ID: lil-788620

ABSTRACT

Clinicians can find patients with one mandibular remaining tooth, and it is difficult to decide if the tooth has to be removed. When a clinician decides to maintain the tooth, it is common to question the masticatory load distribution divided between the tooth and implant. This paper reports a clinical case of patient with an implant/tooth-supported overdenture and elucidates the masticatory efficiency by electromyography activity analysis. The objective of this case report was to describe a clinical case of a patient with an implant/tooth-supported overdenture and to discuss the muscle response to this treatment. Electrical activities of the masseter and anterior temporal surfaces at maximum voluntary contraction were evaluated by electromyography during pre-treatment, immediately post-treatment,15 and 60 days after installation. When patienthas one remaining tooth in good condition, theimplant/tooth-supported overdenture can be recommended, to preserve the periodontal ligament and proprioception, and to minimize bone loss. Electromyography analysis showed that implant/tooth-supported overdenture is a viable treatment alternative, in muscular stand point, when the patient has a remaining tooth with good osseous support...


Os dentistas podem encontrar casos em que o paciente possui apenas um dente mandibular remanescente,sendo difícil decidir se o dente deverá ser extraído. Quando o clínico decide manter este dente, é comum surgirem dúvidas sobre como ocorre a distribuição da carga mastigatória em próteses suportadas por dente e implante. Este artigo relata a resposta muscular por meio de atividade eletromiográfica de um paciente reabilitado com uma prótese inferior implantodentossuportada. O objetivo deste artigo foi descrever este caso clínico e discutir a resposta musculatória neste tipo de tratamento. As atividades eletromiográficas dos músculos massetere temporal anterior superficial foram avaliadas durante o pré-tratamento, imediatamente após a instalação da prótese, 15 e 60 dias pós-tratamento.Foi verificado que quando o paciente tem um dente remanescente em condição de ser mantido, a prótese implantodentossuportada pode ser recomendada como tratamento, para preservação do ligamento periodontal e da propriocepção, e para minimizar a perda óssea. A análise eletromiográfica demonstrou que a prótese implantodentossuportada é uma alternativa viável de tratamento, do ponto de vista muscular, quando o paciente possui um dente remanescente com suporte ósseo adequado...


Subject(s)
Humans , Dental Implantation , Prostheses and Implants
9.
Braz. j. oral sci ; 12(2): 84-89, Apr.-June 2013. ilus
Article in English | LILACS, BBO | ID: lil-694423

ABSTRACT

Aim: To evaluate the influence of plaster condition, dry or not, on the amount of residual monomerin heat-cured acrylic resin. Methods: Thirty acrylic resin specimens (65x10x3 mm) were fabricatedand randomly assigned to 5 groups (n=6). The evaluated resins were heat-cured acrylic resinsby conventional or microwave polymerization techniques and the plaster was previously dried inmicrowave oven in two groups. Each specimen was individually immersed in a test tube containingmethanol (7 days) for surface analysis. In the groups for which internal monomer was evaluated,the specimens were fragmented and the small fragments were weighed prior to immersion inmethanol. The analysis was made by high performance liquid chromatography (HPLC). Datawere analyzed by ANOVA and Tukey test (p<5%) Results: showed statistical differences amongthe groups. Conclusions: The previous plaster drying influenced the residual monomer amountshowing a decrease of these levels.


Subject(s)
Acrylic Resins , Chromatography , Research , Polymers
10.
RPG rev. pos-grad ; 19(2): 50-56, abr.-jun. 012. tab
Article in Portuguese | LILACS, BBO | ID: lil-688226

ABSTRACT

Este estudo teve o propósito de investigar as propriedades flexurais de seis marcas comerciais de resinas compostas indiretas e duas resinas compostas para uso direto. Dez espécimes (2 x 2 x 12 mm) de cada material foram confeccionados de acordo com as recomendações dos fabricantes: Grupo I - Signum (Heraeus Kulzer), Grupo 2 - Solidex (Shofu Inc.), Grupo 3 - Resilab (Wilcos), Grupo 4 - Adoro (Ivoclair Vivadent), Grupo 5 - Admira (Voco), Grupo 6 - Sinfony (3M/Espe), Grupo 7 - Filtek Supreme (3M/ESPE) e Grupo 8 - Venus (Heraeus Kulzer). Os espécimes foram armazenados a 37 graus por 24 horas. Em seguida, foram submetidos ao ensaio de miniflexão na máquina de Ensaio Universal EMIC a uma velocidade de 0,75 mm/min, para determinar o módulo de elasticidade e resistência à flexão três pontos para cada compósito estudado.


Subject(s)
Composite Resins , Elastic Modulus , Fatigue
11.
Braz. dent. sci ; 15(4): 10-13, 2012. ilus, tab
Article in English | LILACS, BBO | ID: lil-694453

ABSTRACT

Objectives: To investigate the effect of the thermal treatment on the bending strength of ceramic bars (VM7) treated by the cementation protocol. Material and Methods: Forty ceramic bars (20 x 4 x 1.2 mm) were constructed and randomly distributed into 2 groups (n=20): NT - without treatment/control and T – with treatment (50°C above the glass transition temperature, for 15 min). All specimens underwent the cementation process in which one surface of the ceramic bar was etched (20 s) with 10% hydrofluoridric acid, followed by air-water jet washing (60 s), drying (30 s), silane agent application and resin cementation. After storage (distilled water/seven days at 37 ºC), the specimens were submitted to 3-point flexure test at 100% humidity/37 ºC (v=1 mm/min, load cell of 10 kgf). Results: The bending strength values and standard deviations (MPa) were: NT: 19.98 (3.17)a; T: 20.45 (4.67)a (one-way ANOVA and Tukey test, σ=0.05). Conclusions: The thermal treatment did not influence on the bending strength mean values of the ceramics studied.


Objetivos: Investigar o efeito do tratamento térmico, na resistência à flexão, de barras cerâmicas (VM7) tratadas pelo protocolo de cimentação. Material e Métodos: Foram confeccionadas 40 barras cerâmicas (20 x 4 x 1.2 mm) e distribuídas randomicamente em 2 grupos (n=20): NT - sem tratamento/controle e T - com tratamento (50°C acima da temperatura de transição de fases, durante 15 min). Todos os espécimes receberam o processo de cimentação onde uma face da barra cerâmica foi condicionada (20 s) com ácido fluorídrico 10%, seguida pela lavagem jato ar-água (60 s), secagem (30 s), aplicação do silano e cimentação resinosa. Após armazenagem (água destilada/sete dias à 37 ºC), as amostras foram submetidas ao ensaio de flexão 3 pontos em 100% umidade à 37 ºC (v=1 mm/min, célula de carga de 10 kgf). Resultados: Os valores de resistência à flexão e os desvios-padrão (MPa) para os grupos foram: NT: 19.98 (3.17)a; T: 20.45 (4.67)a (ANOVA one-way e Teste de Tukey, σ=0.05). Conclusões: Verificou-se que o fator tratamento térmico não influenciou nos valores médios de resistência à flexão da cerâmica estudada.


Subject(s)
Resin Cements , Thermic Treatment
12.
RGO (Porto Alegre) ; 59(2): 237-242, abr.-jun. 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-874581

ABSTRACT

Objetivo: Avaliar o efeito do tratamento por energia de micro-ondas sobre as propriedades de resistência à flexão e microdureza da resina acrílica de ativação química Dencrilay Speed® (Dencril, Pirassununga, Brasil).Métodos: Foram confeccionados 24 corpos-de-prova separados em quatro grupos de acordo com o ciclo de tratamento por energia de micro-ondas. O G1 (controle) não recebeu tratamento algum. Os grupos G2, G3 e G4 foram imersos em 200ml de água destilada e irradiados em micro-ondas a 650W durante 5, 3 e 1 minuto, respectivamente. Cada grupo (n=6) foi submetido ao ensaio de resistência à flexão de três pontos e ao teste de microdureza Vickers (após 48 horas de armazenamento). Resultados: Os valores médios (Mpa) e desvios-padrão para o teste de resistência à flexão foram: G1 86,04 ± 10,32 a; G2 100,1 ± 5,52 ab; G3 102,04 ± 5,41 b; G4 104,81 ± 14,17 b. Os valores médios encontrados em microdureza (VHN) foram: G1- 21,98 ± 0,82 a; G2- 20,15 ± 1,24 b; G3- 19,69 ± 0,91 b; G4- 19,44 ± 0,41 b. Conclusão: O tratamento por energia de micro-ondas elevou a resistência à flexão e reduziu a microdureza da resina acrílica avaliada.


Objective: This study assessed the effectiveness of microwave energy treatment on the flexural resistance and microhardness of the chemically-activated acrylic resin Dencrilay Speed®. Methods: Twenty-four specimens were prepared and divided into 4 groups according to microwave-energy treatment cycle. G1 (control) did not receive any treatment. The specimens in groups G2, G3 and G4 were immersed in 200mL of distilled water and then microwaved in a 650W oven for 5, 3 and 1 minutes, respectively. Each group (n=6) was submitted to a three-point flexural strength test and to a Vickers hardness test after a 48-hour storage. Results: The mean values (MPa) and standard deviations for the flexural strength test were: G1 86.04 ± 10.32 a; G2 100.1 ± 5.52 ab; G3 102, 04 ± 5.41 b; G4 104.81 ± 14.17b. The mean values found for the hardness test (VHN) were: G1-21.98 ± 0.82 a; G2-20.15 ± 1.24 b; G3- 19,69 ± 0.91 b; G4-19.44 ± 0.41 b. Conclusion: Microwave treatment increased the flexural strength and reduced the microhardness of chemically-activated acrylic resins.


Subject(s)
Microwaves , Denture, Complete , Acrylic Resins
13.
Odonto (Säo Bernardo do Campo) ; 19(37): 135-142, jan.-jun.2011. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-789960

ABSTRACT

Avaliar a resistência da união adesiva, pelo ensaio de microtração, de bases para próteses totais confeccionadas com resina acrílica ativada termicamente (Lucitone 550 - Dentsply) a dentes artificiais de resina acrílica (Biotone - Dentsply), submetidos a diferentes condições pós-prensagem e períodos de armazenagem.Metodologia: foram confeccionados 32 conjuntos dente/base de resina acrílica, separados em quatro grupos (n=8) conforme o tempo pós-prensagem até a acrilização (imediatamente após ou 24 h após a prensagem) e período de armazenagem em água destilada (24 horas ou 30 dias, em água destilada à 37°C). Sendo assim, 4 grupos foram formados: G1 (Imediato; -sem armazenagem); G2 (Mediato - sem armazenagem); G3 (Imediato - com armazenagem); e G4 (Mediato - com armazenagem). Os conjuntos dente/base de resina foram seccionados em dois eixos, x e y, com um disco diamantado sob irrigação constante (área adesiva - 1mm2) obtendo-se aproximadamente 96 corpos de prova (cp) por grupo. Imediatamente após o corte, os cp foram fixados em um dispositivo de microtração acoplado a uma máquina de ensaio universal (EMIC-DL-1000, Brasil) e testado com velocidade de 1mm/min. Os dados foram submetidos ao teste Anova e Tukey (=0,05).Resultado: os valores médios (MPa) obtidos foram: G1: 27,82 ±12,68, G2: 29,92 ±13,73, G3 30,09 ±20,48 e G4: 32,51±13,81.Conclusão: as diferentes condições pós-prensagem e períodos de armazenagem não influenciaram na resistência de união adesiva dente/base de resina...


The objective of this study was to compare the tensile bond strengths by the micro tensile test of conventional heat-cured resin denture (Lucitone 550 – DENTSPLY) with acrylic resin denture teeth (Biotone – DENTSPLY), submit in a different polymerization cycle and storage.Methodology: thirty two specimens were fabricated and divided in four groups (n=8): G1 (immediate; without storage); G2 (mediate; without storage); G3 (immediate; with storage); G4 (mediate; with storage). Theses specimens was storage in distilled water until testing and cut in two axis, X and Y, with a diamond disc, getting 12 specimens with ± 1 mm² of adhesive area. The specimens were fixed in a specific device that was fixed in a universal testing machine (EMIC-DL-1000, Brazil) and tested with a cross-speed 1 mm/min.Results: the microtensile bond strengths values was G1 (27,82 ±12,68), G2 (29,92 ±13,73), G3 (30,09 ±20,48) e G4 (32,51±13,81).Conclusion: within the limitations of this study, there no was difference between these groups...


Subject(s)
Humans , Dental Bonding/methods , Acrylic Resins/chemistry , Tooth, Artificial , Materials Testing , Polymerization , Reproducibility of Results , Surface Properties , Tensile Strength , Time Factors
14.
RPG, Rev. Pós-Grad ; 16(2): 63-70, abr.-jun. 2009. tab
Article in Portuguese | LILACS, BBO | ID: biblio-855232

ABSTRACT

O objetivo deste estudo foi comparar a rugosidade superficial de diferentes resinas compostas após polimento com discos Sof-Lex e discos TDV. Foram confeccionados dez espécimes para cada tipo de material restaurador, utilizando uma matriz pré-fabricada, resultando nos grupos: Vênus(VE), Charisma (CA), 4 Season (4S), Opallis (OP), Filtek Supreme (FS), Natural Look (NL), Amaris (AM), EsthetX (EX). Cada grupo foi dividido em três subgrupos, de acordo com a técnica de polimento. No subgrupo C, não foi realizado polimento. No subgrupo S, Foram empregados os discos de lixa Sof-Lex e no subgrupo T, foram empregados os discos de lixa TDV. A rugosidade superficial foi mensurada com um rugosímetro. Os resultados foram analisados pelos testes estatísticos de ANOVA e Tukey (5%), obtendo-se p = 0,00. Os valores de média (± desvio padrão) em Ra (µm) para cada grupo/subgrupo foram: CA/C - 0,13 (± 0,07)A; NL/C - 0,14 (± 0,08)A; VE/C - 0,15 (± 0,12)A; OP/C - 0,16 (± 0,10)A; FS/C - 00,19 (± 0,08)A; 4S/C - 0,19 (± 0,10)A; AM/C - 0,22 (± 0,11)AB; VE - 0,24 (± 0,06)AB; EX/C - 0,26 (± 0,08)AB; CA/S - 0,26 (± 0,05)AB; FS/S - 0,28 (± 0,09)AB; OP/S - 0,32 (± 0,16))AB; EX/S - 0,34 (±0,09)AB; NL/S - 0,35


Subject(s)
Composite Resins , Dental Polishing , Dental Restoration, Permanent , Esthetics, Dental , Nanoparticles , Nanotechnology
15.
Rev. Assoc. Paul. Cir. Dent ; 64(3): 215-219, mai.-jun. 2010.
Article in Portuguese | LILACS, BBO | ID: lil-590281

ABSTRACT

A disfunção temporomandibular é um termo aplicado à condição de dor e/ou de disfunção mastigatória, sendo encontrada em 750f0 da população e tem a maloclusão como um dos possíveis fatores predisponentes. Este artigo relata a seqüência de tratamento de uma paciente que apresentava um posicionamento maxilo-mandibular sugestivo de mordida classe III de Angle, com prognatismo mandibular acentuado, mordida cruzada anterior e ausência de suporte posterior. Observou-se a diminuição marcante da dimensão vertical de oclusão que resultava na condição postural mandibular relatada, o que gerou desconforto, dificuldade mastigatória, sintomatologia dolorosa nos músculos elevadores da mandíbula bilateralmente e assimetria facial. O tratamento de eleição consistiu na recuperação da DVO por meio da instalação de uma prótese temporária removível inferior. Além disto, foi feito um "dispositivo anterior" que possibilitou o equilíbrio de contatos em posições excêntricas, além de proporcionar conforto, função e estética. Concluiu-se que a técnica proposta foi de simples aplicação clínica e determinou remissão da sintomatologia dolorosa, além de facilitar a elaboração do planejamento clínico e sua execução.


Temporomandibular dysfunction is a term applied to a pain and/or masticatory dysfunction con- dition, find in 750f0 of population and has malocclusion as one of the potential predisposition factors. This article report a sequence of treatment in one patient that used to present a maxilo-mandibular position suggesting bite Angle's class 111, with an accented mandibular prognathism, anterior crossbite and absence of posterior support. It was observed a pronounced decrease of vertical occlusion dimen- sion that resulted in a mandibular postura I condition related, that generated discomfort, masticatory difficult, painful symptomatology in the bilateral mandibular elevator rnuscles and facial asymmetry. The selected treatment consisted in a vertical dimension of occlusion recovery through the installation of a lower temporary removable prosthesis. Furthermore, it was made an "anterior appliance" that made possible the contacts equilibrium in eccentrics position also provides comfort, function and esthetic. It was concluded that the technique proposal was the simple clinical application and determined painful symptomatology remission, besides facilitating an elaboration of a clinical planninq and execution.


Subject(s)
Humans , Female , Aged , Denture, Partial, Temporary , Occlusal Splints , Mouth Rehabilitation/methods
16.
RGO (Porto Alegre) ; 58(1): 65-69, jan.-mar. 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-873907

ABSTRACT

Objetivo: Avaliar a influência da posição do molde durante a fase de presa do gesso pedra tipo IV Durone (Dentsply Ind. Com., Rio de Janeiro, Brasil), sobre as propriedades: dureza superficial e rugosidade. Métodos: Foram determinados para o teste de rugosidade dois grupos (n=6) na forma de pastilhas. No primeiro grupo, a superfície da base do dispositivo permaneceu voltada para baixo durante a fase de presa do gesso (N), no segundo grupo esta posição foi invertida, o que se convencionou descrever como ato de emborcar (E). Para a análise foi utilizado um rugosímetro com precisão de leitura de 0,01μm. Quanto à análise da dureza, foram obtidos dois grupos (n=5) com amostras de formato cônico. Os gessos tomaram presa nas mesmas condições de posicionamento molde/modelo descritas para o experimento anterior. A mensuração da dureza foi realizada em um durômetro com ponta penetradora esférica para leitura Rockwell. Foram realizadas três medições para cada corpo de prova em ambos os testes. Resultados: Os dados de dureza (N - 39,8, desvio-padrão = 3,3; E - 30,8, desvio-padrão= 5,6) e de rugosidade (N - 0,67, desvio padrão=0,17; E - 0,74, desvio-padrão= 0,13) submetidos ao teste t-Student (5%) revelou não haver diferenças estatisticamente significantes para o teste de rugosidade (0,489), mas sim para o de dureza (0,014). Conclusão: A variação no posicionamento molde/modelo influenciou nas características finais dos corpos de prova quanto à dureza, visto que aqueles obtidos com a técnica do emborcamento apresentaram menor dureza superficial, já para o quesito rugosidade estas diferenças não tiveram significado estatístico


Objective: To assess the influence of the position of the mold during the setting stage of type IV stone plaster Durone (Dentsply Ind. Com., Rio de Janeiro, Brazil), on the following properties: surface hardness and roughness. Methods: For the roughness test, two groups (n=6) in the form of pellets were prepared. In the first group, the surface of the base of the device was turned down during the plaster setting stage (N), in the second group this position was inverted, which has been described as an act of capsize it (E). For analysis, a roughness meter with reading precision of 0.01 μm was used. With regard to the hardness analysis, two groups with conical-shaped samples were obtained. The plasters were left to set under the same conditions of the mold/model position described for the previous experiment. Hardness measurement was performed in a durometer with a spherical penetrating tip for Rockwell readout. Three measurements were performed for each test specimen in both tests. Results: The hardness (N - 39.8, standard deviation = 3.3, E - 30.8, standard deviation = 5.6) and roughness data (N - 0.67, standard deviation = 0.17, E - 0.74, standard deviation = 0.13) submitted to the Student's-t test (5%) showed no statistically significant differences for the roughness test (0.489), but showed statistically significant differences for the hardness test (0.014). Conclusion: The variation in the mold/model position influenced the final characteristics of the specimens in terms of hardness, since those obtained with the capsize technique showed lower surface hardness, whereas for roughness these differences were not statistically significant.


Subject(s)
Dental Impression Materials , Calcium Sulfate , Hardness Tests
17.
Braz. dent. sci ; 12(3): 50-55, jul.-set. 2009. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-587929

ABSTRACT

O objetivo neste trabalho foi visualizar possíveis alterações do posicionamento da ATM em pacientes desdentados que não usavam prótese total ou que a utilizavam apenas no arco superior. Para tanto, avaliou-se a posição da cabeça da mandíbula na fossa mandibular por meio de radiografia transcraniana lateral, realizada antes e após tratamento protético oclusal reabilitador. Foram obtidos 38 exames radiográficos separados em dois grupos, dos quais somente a posição de boca fechada foi utilizada para mensuração, para que a cabeça da mandíbula estivesse posicionada no interior da fossa mandibular. As medidas foram realizadas em 3 regiões entre a cabeça da mandíbula e a fossa mandibular em ambas as articulações (direita e esquerda) de cada paciente através de traçado manual. Após análise dos valores encontrados, pôde-se afirmar que não houve alteração significativa das posições anterior, superior e posterior da relação cabeça da mandíbula e fossa mandibular da ATM esquerda dos indivíduos. Contudo, do lado direito houve um deslocamento posterior da cabeça da mandíbula em relação à fossa mandibular após a colocação da nova prótese total.


The objective of this study was to visualize significant alterations of the positioning of ATM in edentulous patientswho did not make use of total prosthesis or that used it only in the superior arc. In this research, it was evaluated thejaw head position in pit jaw by lateral transcranial radiography, carried through before and after prosthetic treatment, through manual tracing. 38 radiographic examinations were taken (19 before and 19 after the prosthetic treatment), in which only the closed mouth position was used for measurement, so that the head of the jaw was located in the interior of pit jaw. The measures had been carried through in 3 regions between jaw head and pit jaw in both the joints (right andleft) of each patient. After analysis of the found values, it could be stated that it did not have significant alteration of the anterior, superior and posterior positions of the relation head of the jaw and pit jaw of the left ATM of the individuals. However, the right side had a posterior displacement of the jaw head in relation to pit jaw after the rank of the prosthesis.


Subject(s)
Temporomandibular Joint , Mouth, Edentulous , Mandible , Denture, Complete
18.
Rev. Assoc. Paul. Cir. Dent ; 63(3): 202-206, maio-jun. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-534476

ABSTRACT

Este caso clínico apresenta a utilização de um paralelizador intrabucal (ParaIAB) que otimiza a confecção do preparo de boca em reabilitação por prótese parcial removível. Esta técnica permite delinear, preparar e calibrar as retenções diretamente na cavidade bucal, tornando o preparo mais rápido e eficiente. Em um caso clínico classe III de Kennedy, foi realizado o delineamento e confeccionados planos-guia nos dentes suportes. Devido à possibilidade de delineamento dentro da cavidade bucal e maior precisão, não houve necessidade de retoques nos preparos após conferência com delineador de bancada e a quantidade de moldagens de conferência diminuiu.


This clinical study presents an intraoral parallelometer device (ParaIAB), which optimizes tooth preparation on removable partial denture prostheses rehabilitation. This technique allows recontouring, surveyor tooth preparation and check retention directly on mouth, saving time due to easier preparation technique. In a Kennedy Class III clinical case, abutment teeth were recontoured and prepared for guiding planes with ParaIAB directly on mouth. Because its precision and easy handling, re-preparing were not needed, what was checked with an intraoral parallelometer. Additionally, number of impressions decreased using this device.


Subject(s)
Humans , Female , Adult , Dental Prosthesis , Denture, Partial, Removable
19.
RFO UPF ; 12(2): 32-36, 31/08/2007. tab
Article in Portuguese | LILACS, BBO | ID: biblio-873342

ABSTRACT

Os gessos são amplamente utilizados na odontologia com diferentes propósitos. Apesar de diversos autores advogarem o controle preciso da proporção água/pó para a utilização dos produtos da gipsita, na prática geralmente os profissionais não respeitam a proporção preconizada pelo fabricante, realizando o proporcionamento de forma empírica. Este estudo teve como objetivo analisar a influência do método de aglutinação da mistura água no pó ou pó na água, e da relação água/pó aleatória sobre a resistência à compressão seca de dois tipos de gesso, e também propor a substituição da proveta por um gral de borracha experimental. Neste estudo foram avaliados gessos tipo lll e tipo lV (n = 8). Para cada tipo de gesso foram definidas cinco formas de aglutinação dando origem aos grupos: Gc-Grupo de controle (recomendação do fabricante), Gl-BGP (balança, gral graduado e pó sobre a água), Gll-BPA (balança, proveta e água sobre o pó), Glll-AGP (aglutinação aleatória, gral graduado e pó sobre a água), GlV-BAA (balança, aglutinação aleatória e água sobre o pó). No total, foram testados 80 corpos- de-prova. Após sete dias de armazenagem a 37ºC, as amostras de 2 cm de diâmetro por 4 cm de altura foram submetidas ao teste de compressão em máquina de ensaio universal. De acordo com os resultados (kgf) obtidos pelo teste de compressão para o gesso tipo lll, não houve influência do modo de aglutinação (p = 0,25). Já para o gesso tipo lV, houve diferença entre os tratamentos (p=0,03), sendo que a utilização do gral graduado experimental possibilitou a obtenção de valores de resistência similares aos dos demais grupos


Subject(s)
Dentistry , Tensile Strength , Calcium Sulfate
20.
RPG rev. pos-grad ; 13(3): 229-235, jul.-set. 2006. ilus, graf, tab
Article in Portuguese | LILACS, BBO | ID: lil-529396

ABSTRACT

Este trabalho teve como proposta avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto, foram confeccionados corpos-de-prova nas dimensões de 2,5 mm x 10 mm x 65 mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão, no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 - grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido; e dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições - à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água(Vf2). Os resultados mostraram diferenças estatisticamente significantes, nos quais o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e, a princípio, pareceu haver uma relação de causa e efeito entre os elevados níveis de monômero residual encontrados nestes grupos e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30 minutos da resina de ativação química propiciou um ganho em qualidade do material para as características avaliadas.


Subject(s)
Acrylic Resins , Denture Bases , Dental Materials , Denture, Complete , Shear Strength
SELECTION OF CITATIONS
SEARCH DETAIL